A white high-roof van at a lakeside campsite, its roof tracker tilted open to one side, with mountains and pine forest behind

Founded in Silicon Valley, California · Serving customers worldwide

Multi-Axis Smart Solar-Tracking PV Systems

Relentlessly Harvesting Solar Energy from Sunrise to Sunset

Scroll to see how tracking works

Why tracking

The sun moves.
The panel should too.

A fixed panel faces the sun only around midday. Tracking keeps it facing the sun from sunrise to sunset.

Energy Gain

In January in
tracking beats flat by 144%

Clear-sky model for installed, on the 15th of each month. A flat panel’s back rests on the roof, so it makes no rear-side power.

Roof under the tracker
6.88kWh
Dual-axis tracking (bifacial)
2.82kWh
Flat on the roof 0°
10 h 9 m
Daylight
+4.06kWh
Tracking extra

From the rear +199 Wh

Clear-sky model estimate, not measured data.

How this is computed

Reference: Trina Solar Vertex N TSM-NEG21C.20, 730 W bin. The official TSM_EN_2025_C datasheet specifies nominal bifaciality 80% (±5%), NOCT 43 °C (±2 °C), power temperature coefficient −0.29%/°C and dimensions 2.384 × 1.303 m. Tracking and flat use those same module parameters. Selected front-rated installed capacity: 1 kW. The 730 W, 900 W and 1 kW choices compare system capacities; they are not three single-module ratings in this series. With the same mounting geometry and loss assumptions, watts and every energy term scale by capacity in kW; temperature and percentage gain stay unchanged. An actual larger array changes layout and shading and requires its own model. Both sides use Ineichen–Perez clear sky and a shared Hay–Davies split: circumsolar diffuse joins sunlight from the sun direction; the remainder is isotropic skylight. Both faces and the roof use that same split and shadow treatment. A near-horizon projection limit preserves horizontal irradiance. Ambient temperature is 20 °C and the generic system-loss factor is 0.86. Direct and circumsolar light use ASHRAE incidence-angle correction; remaining skylight and reflection use an assumed 0.95 transmission factor. The flat panel lies directly on the roof: its back rests against the roof and receives no light, so only the front counts; a horizontal front sees no roof either, so the flat result does not depend on roof color. The tracker is raised above the roof. Analytical polygon view factors are integrated over a 48 × 96 roof grid with 4 × 4 shadow probes per cell. The module obstructs roof skylight; visible rear skylight is added separately. Current assumptions: 60% roof reflectance; a 4 × 2 m horizontal roof with its long axis north–south; 0.15 m lowest-edge clearance for the tracker, with its center rising with tilt; no support shading; 2% rear mismatch. The 15 cm lowest-edge clearance is a scenario assumption, not a measured product dimension; geometry and reflectance are assumed. Tracker effective irradiance = front effective irradiance + rear effective irradiance × 0.80 × 0.98. Both faces affect temperature; power is integrated every 5 minutes. Net rear contribution = combined output minus a front-only calculation. The front-only calculation uses the same front irradiance without rear-induced heating. The net increment therefore deducts the extra heating loss on the front; it is not roof-reflected electricity alone. Today at 1 kW: tracking 6.68 + 0.20 = 6.88 kWh; flat 2.82 kWh, front only; figures rounded independently. Gain = total tracking energy / flat energy − 1, so a lighter roof raises the gain along with the tracker’s rear output. The chart keeps a common 1 kW comparison axis so capacity changes remain visible. Ground beyond the roof, multiple reflections, cloud, nearby obstructions and soiling are excluded. Ideal full-travel tracking is not the existing 720 W product’s 0–45° mechanical range; this calculator reference does not replace reviewed product-page specifications. Local standard time, no daylight saving. Representative clear-sky days are not annual yield. Model home-roof-bifacial-4.0.0 is not calibrated to vehicle measurements or equivalent to the device gain reported against an optimal fixed-tilt reference with measured weather. Trina Solar datasheet ↗

250 W500 W750 W1000 W6:009:0012:0015:0018:0021:00Sunrise 6:58Sunset 17:07Dual-axis tracking (bifacial)Flat on the roof 0°Tracking extra +4.06 kWh

Bifacial generation

Lift it off the roof.
The back works too.

A bifacial module makes power on both faces. Raised on the tracker, its back catches light reflected off the roof and from the open sky. Laid flat, the back rests on the roof and gets none.

From the rear

Los Angeles · January 15 · 1 kW, the day in the chart above.

Sunlight on the tracker’s front; roof reflection and skylight on its backSide view. The sun is 50° up and the tracker faces it at a 40° tilt, lowest edge 15 cm above the roof. The panel shades the roof beneath it; sunlit roof beyond the shadow scatters light onto the back, which also sees part of the sky.SunlightRear sideRoof reflectionSkylight15 cmPanel shadowSunlit roof

Flat on the roof: the back touches the roof and gets no light.

Light-path illustration, not an energy simulation.

What the chart includesThe tracking curve includes rear-side output from roof reflection and skylight; the flat curve counts the front only. A lighter roof raises tracking and leaves flat unchanged.

What affects rear-side generation?

Roof reflectance, clearance, tilt and the panel’s own shadow decide how much light reaches the back: sunlit roof reflects the most, the shaded roof under the panel very little. The 80% bifaciality is the Trina 730 W module’s nominal rating, the rear’s response relative to the front, not the system’s extra energy. Reflectance and the 15 cm clearance are scenario assumptions.

Reference: Sandia bifacial PV modeling ↗

OUR FLAGSHIP

Rooftop solar tracking

720W

Made for the roof.
Open to the sun.

Explore 720 W
720 W rooftop solar tracker, front three-quarter view
One continuous array. Two axes of tracking.A closer look

720 W · UP CLOSE

Rise toward the sun.
Stow close to the roof.

From the module frame to the complete base, explore how elevation and rotation come together.

Explore the details
720 W rooftop solar tracker, front view
2496 × 1303 mm

Assembly length × width

98.27 × 51.30 in

123 mm

Assembly height when stowed

4.84 in

Dual-axis

Azimuth and elevation adjustment

ANOTHER ROOFTOP OPTION

Two panels. Follow the sun.

910 W solar assembly front view with two adjacent panels and silver base frame
02 / ROOFTOP TRACKING

910W

Two 455 W panels. One complete frame.

Explore the panels, supports and drive details, then discuss an installation for your vehicle and roof.

Explore 910 W Submit interest

YOUR NEXT STEP

Your next chapter.
Follow the sun.

Tell us the product you have in mind, the quantity and your timing.

Submit interest

Register your interest. No obligation to buy.

SUN-ZENITHFollow the light.